Variable operating time actuators SQVEx and SQRVEx

With SQVEx .2 part-turn actuators for open-close duty and SQRVEx .2 for modulating duty paired with ACVExC .2 actuator controls, the proven AUMA SQ/SQR range is enhanced by variable operating time models. AUMA is spearheading market technology, offering a wide operating time range with a ratio of up to 1:10.

 

Actuators of the SQVEx type range are rated for open-close duty and positioning duty (classes A and B) / (short-time duty S2 – 15 min).

 

Actuators of the SQRVEx type range are rated for modulating duty (class C) S4 – 25 %.

Description

Design features SQVEx

  • Torque range from 150 Nm to 2,400 Nm
  • Swing angle from 75° to 105°
  • Operating times for 90° from 4 s to 360 s
  • Limit and torque sensing
  • Mains connection: 1-phase and 3-phase
  • Handwheel for manual operation
  • Mechanical position indicator

Design features SQRVEx

  • Torque range from 150 Nm to 2,400 Nm
  • Modulating torque range from 75 Nm to 1,200 Nm
  • Max. number of starts 1,500 c/h
  • Swing angle from 75° to 105°
  • Operating times for 90° from 4 s to 360 s
  • Limit and torque sensing
  • Mains connection: 1-phase and 3-phase
  • Handwheel for manual operation
  • Mechanical position indicator

Ambient conditions

  • High enclosure protection
  • High quality corrosion protection
  • Wide ambient temperature ranges

Options

  • Intermediate position switches
  • Switches in tandem version
  • Remote position transmitter
  • Magnetic limit and torque transmitter

Interfaces

  • Electrical connection via AUMA plug/socket connector (terminals as an option)
  • Cable entries in different versions
  • Output drive types according to DIN and EN ISO standards

Interface and functional propertie

  • Programmable, potential-free output contacts for status signalling
  • Soft start and stop for gentle valve operation
  • Avoiding pressure surge by an operating time profile
  • EMERGENCY behaviour and safety behaviour with separate operating time setpoints
  • Process controller (PID)
  • Fieldbus control
  • Behaviour in case of emergency situations and communication loss (programmable)
  • Operation data logging
  • Bluetooth interface to notebook and Android tablet.

Approvals

    • Europe – ATEX Standard: II 2G Ex db eb IIC T4 oder T3 Gb II 2G Ex h IIC T4 oder T3 Gb Optional: II 2G Ex db IIC T4 oder T3 Gb II 2G Ex db eb IIB T3 Gb II 2G Ex db IIB T3 Gb II 2G Ex h IIB T3 Gb
 
  • International level/Australia – IECStandard: Ex db eb IIC T4 oder T3 Gb Optional: Ex db IIC T4 oder T3 Gb Ex db eb IIB T3 Gb Ex db IIB T3 Gb